| Model | X-Ray Source | Detector | Object Size | Object Weight | Detector Spatial Resolution | System Advantages | System Limitations | Typical Objects |
 ACTIS 150/90 Desktop | 90 kV Microfocus | 100/50 mm Dual-Field Image Intensifier | 150 mm dia., 150 mm tall | 10 kg | 7.5 lp/mm in 4 in. mode; 11 lp/mm in 2 in. mode | Small System footprint, includes shield cabinet. Includes real-time radiography. 150 mm FOV. | Low x-ray energy limits you to small, light-density objects. | Plastics, fibrous materials,organic materials, small light metals. |
 ACTIS 150/130 Desktop | 130 kV | 100/50 mm Dual-Field Image Intensifier | 150 mm dia., 150 mm tall | 10 kg | 7.5 lp/mm in 4 in. mode; 11 lp/mm in 2 in. mode | Small footprint ; includes shielding cabinet. Provides real-time radiography. 150 mm FOV. | Low x-ray energy limits you to small, light-density objects | Plastics, light metals, organic structures, small ceramics. |
 ACTIS 200/225 | 225 kV | 150 mm Image Intensifier | 200 mm dia., 250 mm tall | 20 kg | 4.4 lp/mm | Best microfocus tube technology. One-micron focal spot. Anode filaments are replaceable. 1k X 1k digital camera standard. | Higher initial system cost. Requires shield cabinet or shielded room. | Plastics, ceramics, light metals, small ferrous materials, organic structures. |